服务器磁盘阵列问题
作者:存储与备份 来源:网络收集 日期:2007-08-02
今天开机出现下面提示,对阵列不太熟悉。请各位帮忙。
problem is detected with array:1
critical status:
a disk member of a mirrored array has failed or is not responding.the array is still functional,but fault tolerance is disabled.
1.identify which drive has failed with the (3) define array menu option.
2.power off the system replace the failed drive.
3.restart the system and enter the fastbuild9tm) setup menu.
4.choose the(50 option to rebuild the array with replacement drive.
.......ctrl f.......
.......esc......
服务器材是联想万全1000,阵列卡是:promise Fast Trak100.
我轮换接一个硬盘启动电脑。其中一个硬盘不能启动系统。我把不能启动的那个接到主板的IDE口上,可以启动系统。这是正常的吗?
我试着按CTRL F设置了阵列,但不知道是否设置好了。怎么可以检查设置正确与否?
另外:怎么知道是RAID0,还是RAID1或RAID3?
up
一般启动时可以看到,默认id7
RAID 1
problem is detected with array:1
critical status:
a disk member of a mirrored array has failed or is not responding.the array is still functional,but fault tolerance is disabled
说得很清楚嘛:
阵列1出了问题,很严重,因为构成镜像系统的两块盘有一块坏了,虽然数据都在,但是镜像已经失效了,数据不再受容错保护,快换掉坏盘吧。